Home 제품/서비스 Implant

Implant

Implant
SB FIXTURE. Sustainable Beauty: - Simple restoration process, digital and conventional. - Prosthetic flexibility, stock abutment and customs. - Reliable teeth white esthetics, single and full missing case. Stress Free: - Reduces compression pressure on hard cortical bone. - Improves stress distribution. - Elevate BIC in the cortical part during functioning. Smart Insertion: - Fast and controlled penetration into bone. - Specific screw secures stability in all bone types. Save Bone: - Maximize bone preservation - Apex with drilling blades enables smaller osteotomy. - Dome type apex makes sinus floor elevates safely. Simple Abutment: - One connection in every diameter. - Platform switching concept makes soft tissue healthy. - Everlasting gingival pink esthetics. Stable Connection: - 11' morse taper connection with hexagonal interlocking. - Secure and stable fit between fixture and abutment. - Tight sealing prevents joint instability and microbial leakage. B&MEDI surface treatment analysis by SEM. Microscopic characteristics of SB fixtures are area specific roughness through treating surface enhancement method. It has a specific roughness on the two parts as belows: Top portion: Finished surface, Connective tissue attachment Top part of the fixture, soft tissue attachment takes place predominantly on the body. For this reason the coronal implant design must be adapted to these requirements. The finished surface with anodizing offers a wide space for the epithelial attachments and stabilizes connective tissue. Body portion: Blasted, Etched surface, Osseous anchoring The blasted and etched surface offers the ideal coarseness for osseous integration. The surface enhancement method for titanium implants consists of three steps: ➀ Removing surface contaminants from the surface treated titanium implant and activating the surface ➁ Removing the oxide layer of the titanium implant that has been previously surface-treated using electropolishing ➂ Neutralizing residual acid and removing contaminants from electrolytically polished surfaces As a result, the oxide layer generated by the surface enhancement method removes contaminants remaining on the surface of implant, and also neutralizes acid on the surface of implant. In addition, the success rate of surgery can be increased by minimizing the inflammatory reaction caused by contaminants during implant procedures.
SB One & Only Prosthetic Platform. Regardless of fixture diameter, it is simply designed that the fixture can be implanted with one fixture mount and one implant driver. -SB Implant Fixture (SLA Surface). SB Implant Surgical Kit. Everything in the Box : Pointing, drilling, depth, tapping, pick-up, and all what you need.
Cover Screw. Mushroom Cover Screw (for vertical GBR). Check out Our Surgical Kit!
Fixture Mount: Fixture Mount, Quick & Easy. Guide Implant Surgery, Impression Coping, Temporary Abutment.
SB IMPRESSION. -SB True Healing Abutment (THA): When sealing with a True Healing Abutment(THA) a taller screw sticking via the gum is inserted into the implant. This type of 'narrow', 'S-lines' recovery abutments mildew the gum into the favored form for the excellent gum contour. If the gums are sutured with a THA following implant surgery, gingiva will be covered over implant for protection, but also is going to find implant location quickly. Cover screws are indicated with inside the following instances: bone graft surgery, sinus lift, and vertical & horizontal bone graft. The primary stability of the implant is insufficient with torque values much less than 30 N·cm on installation. -SB Healing Abutment: Healing abutments are indicated withinside the following instances: The stability of the implant is good enough with torque values exceeding 30 N·cm on set up. The affected person now no longer smokes. No bone graft was changed into carried out at the set up of the implant. No provisional denture is worn on the area of the surgery.
-Impression Coping: SB offers a range of impression coping components, providing a choice between analog or digital impression taking protocols. A wide variety of components are available for either open-mouth or closed-mouth type impression procedures, for all restoration type. When clinician choose analog, open moth impression procedure, either an open tray or closed tray technique is chosen by the doctor, they may then choose from a range of either analog or CAD/CAM components. Generally, pick up impression coping for open tray technique is highly precise procedures. In addition to the products available for these protocols, SB offers a wide variety of components which enable customization of parts for specific implant sites, whether wide or narrow, anterior or posterior. The design of these components enables flexibility and simple, accurate restoration planning for single tooth, bridge or a full denture. -Transfer Impression Coping (Closed Tray) -Pick-up Impression Coping (Open Tray) -Bite/Scan Impression Coping (Bite Tray) - Intra Oral Scan [Impression Coping Process] -SB Lab Analog
-Bite Scan Abutment: Bite / Scan abutment devices and technology have substantially simplified the complex processes involved in the conventional procedure applied for restoration, and clinicians now express a greater preference for dual-bite impression or virtual devices due to their superior accuracy and simplification of the workflow. Able to obtain precise scan data through two library conformity groove. Enabling one healing scan body to control library conformity. Able to check the height of scan body through the number of groove on the occulusion. Carrier Holder: Carrier Holder fits exactly on the bite/scan abutment, and allows to transfer easily and prevents it from contaminants and dropping. [Bite Scan Abutment Work-Flows] Convensional Impression > Model Scan > Virtual Model > CAD > CAM. or Intra Oral Scan > Virtual Model > CAD > CAM.
SB ABUTMENT. -SB Cemented Abutment (Hex type) -SB Cemented Abutment (Non-Hex type) -SB Angled Abutment (Length 7mm)
-SB Solid Abutment -SB Temporary Abutment -SB Link Abutment: SB Link(Ti-base) abutment for CAD-CAM prostheses. Zirconia crown made by CAM work connected with SBLH/SBLN by the CLDT in the lab. or by the doctor in the chairside also.
-SB Multi Unit Abutment (MUA): In 2017 FDI announced 'PIDP'.(Peri Implant Disease Project) to global awareness about peri implant disease. Almost every implant pathogenesis arose from fixture - abutment junction (FAJ) structure and location. SB developed several strategies about 'SB plan, Sustainable Body fixture plan'. SB MUA is one of SB sustainable protocols. SB MUA moves 'FAJ location' from subgingival 'deep' bone level to equigingival 'visible' soft tissue level. Also SB MUA converts 'FAJ structure' from internal 'weak' wall con- cept to external 'thick and strong' wall concept. Another advantage about SB MUA is inter-implant supra structure parallelism keeps easily and quickly whether sub-structure's relation is parallel or not. This characteristics are good for rehabilitating complete edentulous cases, so called 'All - on - X' modality. Multi Unit Abutment Straight (One Piece), Multi Unit Abutment Angled(17° / 30°), Multi Unit Angled Handle. [SB Multi Unit Abutment Work-Flow] Straight or Angled (17°/30°) > Scan Body > Lab Analog > Cylinder(4.5mm) AMC45 or Cylinder(6.5mm) AMC65 > Mini Screw AMCS. -SB Custom Abutment: Custom abutments can be privately fabricated for every patient easily, they can be fabricated with CAD/CAM milling technique in a very short time. The biggest problem with stock abutments was that tissue compatibility could have not been achieved easily, and the stock abutments are insufficient for the angulated implants. But custom abutments are unique and made for individual patients.
Compatible with Various Implant Systems. -Fabricate Custom Abutment and Crown at the Same Time, Even Though Modelless Case Also -Perfect Fit with 1:1 Milled Crown -Modificable 1µm Offset fabrication tolerance: ±3µm -Medical Grade V Titanium Same as Fixture [Custom Abutment Work-Flow] -Analog: Coping(Transfer / Pick-up / Bite-Scan) > Conventional Impression > Lab Analog > Model Scan > Virtual Model > Library Titanium Blank Connection > CAD / CAM -Digital: Coping(Transfer / Pick-up / Bite-Scan) > Intra Oral Scan > Virtual Model > Library Titanium Blank Connection > CAD / CAM